The Volt Safety LVR-KIT is a low-voltage rescue kit rated up to 1000V, designed for trained safety observers to assist someone in contact with live LV equipment. Built to meet AS/NZS 4836:2011 standards, the LVR-KIT provides everything needed for safe, rapid response on low-voltage switchboards in Australian workplaces.
Switchboard rescue work demands immediate, compliant action when a worker comes into contact with live electrical equipment. Unlike generic first-aid kits, the LVR-KIT is purpose-built for low-voltage emergencies, eliminating guesswork and ensuring that every tool meets safety-regulation requirements. Class 0 insulated gloves, a non-conductive crook, fire blanket, and emergency isolation signage work together to protect rescuer and victim alike. The waterproof carry bag doubles as a water bucket for burn treatment, and high-visibility reflective lettering ensures the kit is findable in low-light or blackout conditions.
Electricians, safety observers, and facilities managers choose the LVR-KIT because it provides a complete, standards-compliant rescue setup at a single grab point. No assembly required, no missing components, no improvisation. The kit is stored near the switchboard or with the designated safety observer, ready to deploy in seconds. Every six months, a quick check of gloves, batteries, dressing, and bag integrity ensures readiness without the cost and complexity of managing individual components.
- Complies with AS/NZS 4836:2011 - the Australian standard for safe work on low-voltage switchboards, covering rescue tools, PPE, and emergency procedures for licensed electrical work.
- Class 0 insulated gloves (1000V-rated) - Size 11 universal fit, marked "Rescue Only" to prevent accidental use in routine work and ensure they remain reserved for emergency response.
- Non-conductive insulated crook - safely pulls someone away from live contact without risk of electrocution to the rescuer, tested and rated for LV duty.
- Waterproof, reflective rescue bag - heavy-duty carrying case with day-night high-visibility lettering for fast location in dark conditions, and doubles as a water bucket for emergency burns treatment.
- Fire blanket (AS/NZS 3504, 1.8m x 1.2m) - for smothering electrical fires or wrapping burns injuries during transport or initial care.
- Multi-trauma burns dressing - sterile, ready-to-use dressing for immediate first aid on electrical burn injuries.
- LED torch with batteries - non-conductive, waterproof torch for visibility in dark switchboard rooms or during blackout emergencies.
- Emergency isolation sign - printed, laminated "Isolate Here in Emergency" sign with string attachment for clear indication of the isolation point.
- First-aid quick-reference booklet - portable guide to assist trained safety observers and rescuers through emergency response steps on site.
- Designed for licensed work only - not for general electrical work or untrained use; the kit assumes rescuer competence and compliance with AS/NZS 4836 training requirements.
- Fault-finding on live 230-240V switchboards - where trained safety observers must be present and equipped to respond to accidental contact with live parts during isolation or testing work.
- Utilities and network provider depots - facilities managing LV distribution equipment where rescue readiness is a regulatory requirement and staff must have immediate access to compliant kits.
- Facilities with on-site electrical switchboards - multi-unit residential, commercial, or industrial buildings where a designated safety observer holds the kit near the main or distribution board.
- Emergency services and transport depots - public transport, emergency response, and utility maintenance teams performing live-work or standby rescue on LV equipment.
- Training and competency verification - used in AS/NZS 4836 rescue training courses to familiarise licensed electricians and observers with standard-compliant tools.
- Workplace safety audits - meets audit and compliance requirements for organisations working on or near live electrical switchboards.
- Standby safety observer stations - deployed near switchboards in workshops, electrical depots, and industrial facilities where a trained observer must be immediately available.
The Volt Safety LVR-KIT is not suitable for high-voltage work, outdoor exposed locations, or untrained personnel. It is designed exclusively for low-voltage rescue by workers who have completed AS/NZS 4836 training and hold current competency certification.
Verified Sparky Direct customer reviews: Volt Safety LVR-KIT (LVR-KIT)
"Great quality product at a great price." - Sue
"Good quality product, received on time and in good condition." - David
"Great product, essential for the electrical trade." - Sue
Delivery varies by location, please see the expected timeframe to receive your product below:
Metro: 1-3 business days
Regional: 1-6 business days
If you are unavailable at the time of delivery re-delivery fees may apply.
- 14 days return / Change of mind
- Client to pay the postage to return goods
- Goods to be in original undamaged packaging
- Warranty on products is determined by the manufacturer.
- Contact us to discuss your claim
- After you have received authorisation to return,
- Post back the product,
- We will return the product to the manufacture and either refund or replace the item as per your instructions.
100-Day Fuss-Free Returns
We want you to love what you buy-but if you change your mind, that's okay too. That's why Sparky Direct offers a .
- Items must be unused, with all parts, accessories, and original packaging.
- We can't accept returns if the product is damaged, incomplete, or not in resalable condition.
- Proof of purchase is required.
- Return shipping is the responsibility of the customer.
If your item isn't in its original condition, please contact us before returning it-we might save you time and money.
All products come with a manufacturer's or supplier's warranty
- Warranty starts from the Invoice Date
- Some suppliers offer in-home warranties and handle claims directly, so you won't need to uninstall or return the product. with us to check if your product qualifies.
- Sparky Direct isn't responsible for losses caused by product failure.
- Warranties are void if products aren't installed by a licensed electrician.
Damaged or Faulty Goods
If your order arrives damaged or is faulty, let us know within 24 hours.
- Sparky Direct will pay for return shipping via an emailed return label.
- If the fault is confirmed, we will send you a replacement item or provide a refund.
Contact us via our to arrange the return.
Exclusions
We can't accept returns for:
- Items that have been installed, modified, or used
- Clearance, End of life, Discontinued, or special order items (unless faulty)
- All PPE Items
- Goods returned without original packaging or proof of purchase
How to Request a Return
- our customer service team with your order number.
- Confirm it's eligible under our return or warranty policy.
- Pack the item securely and return it using a trackable service.
- Once we receive and inspect it, we'll process your refund or replacement.
Warranty starts from Invoice Date
Domestic Use: 1 Year
Commercial Use: 1 Year
Warranty Method: Return to Sparky Direct