12V 100Ah Lithium Battery LiFePO4 M8/F12
Each battery is fitted with an internal battery management system to provide safe charging and discharging at all times. This system provides internal short circuit, over temperature and under/over voltage cut off. Can be wired in series and/or parallel. When used in series each battery will need to be discharged to cut off before connecting so that all cells are all balanced.
Factory supplied at 30% charge for safety compliance. Must be charged fully before use.
Suitable for recharging with the mains battery charger models listed in the accessories below.
Excessive temperatures over 65ºC can effect the ABS housing. Need to be well ventilated in warm conditions. Not for use in engine bays.
Important Note for Users Connecting This Battery In Series.
Due to a supplier error the shipping box and battery label is marked showing that this battery is not suitable for in series wiring. This is incorrect. The battery IS suitable for series wiring between 12-48V DC, up to 4 units. We apologise for any confusion.
- Internal battery management system for safe charging and discharging.
- Drop in replacement for standard lead acid 90-100Ah batteries (check dimensions)
- Half the weight of traditional lead acid batteries.
- Less discharge when in storage compared with traditional lead acid batteries.
- Longer service life compared to lead acid.
- Longer run time compared to lead acid.
- 100A DISCHARGE BMS
- 5 YEAR WARRANTY
- Altronics Code: SL4576B
- I/N: 17118
- Barcode: 9321758242780
- Shipping Weight: 10.74000Kg
- Packaging Sizes
- EACH: 1
- CARTON: 1
- LAYER: 15
- SHPPER: 60
- PALLET: 60
- General
- Dimensions: 330 x 172 x 215mm
- Overall Weight: 13kg
- Terminal Type: M8 / F12
- Connection: 12-48V max 4 in series, no limit in parallel.
- Note: When used in series each battery will need to be discharged to cut off before connecting so that all cells are all balanced.
- Case Material: ABS
- Case IP Rating: IP56
- Cell Type: Prismatic
- Certification: CB/CE, UN38.3, UL1642 @ cell.
- Shipping Class: UN3480, Class 9
- Battery Module Specification
- Nominal Voltage: 12.8V @ 25°C, 0.2C
- Capacity: 100Ah @ 25°C, 0.2C
- Operating Parameters
- Charging Voltage: 13.8 - 14.4V
- Discharging Voltage: 9.2V-11.2V (Recommended 11.8V)
- Charging Current: 100A max, Recommended 50A
- Max Constant Discharge: 100A
- Pulse Discharge: 300A for 3S
- Temperature
- Charge Range: 0 to 45°C
- Discharge Range: -20 to 60°C
- Storage Range: -20 to 45°C
- Service Life
- Design Life: >20 years @ 25°C, 0.2C
- Cycle Life (25° C,0.2C): >4000 times (90% DOD to 80% end)
- Cycle Life (25° C,0.5C): >6000 cycles (100% DOD to 50% end)
- BMS Parameters
- Charging
- Cell Voltage Protection: 3.7V Delay 1-2S (Recover when discharge current >1A or cell voltage <3.38v or="" module="" voltage="" 13="" 52v="" li="">
- Module Voltage Protection: 14.8V Delay 1-2S (Recover when discharge current >1A or cell voltage <3.38v or="" module="" voltage="" 13="" 52v="" li="">
- Over Charging Current 1: 100-101A Delay 50-1500mS (Turn to pre-charge mode and try to recover in every 3 minutes)
- Over Charging Current 2: >300A Delay 2-3S (Turn to pre-charge mode and try to recover in every 3 minutes)
- Temperature Protection: <-10°C or >70°C, Delay 1-2S (Recovery when >0°C or <60°C)
- Discharging
- Cell Voltage Protection: 2.7V (Recover when charge current >1A or cell voltage >2.6V or module voltage >10.4V)
- Module Voltage Protection: 10.8V Delay 1-2S (Recover when charge current >1A or cell voltage >2.95V or module voltage >11.8V)
- Over Discharging Current 1: 300-360A Delay 50-200mS (Recover when charging current >1A, or recover in every 60S)
- Over Discharging Current 2: >360A Delay 100-300uS (Recover when charging current >1A, or recover in every 60S)
- Short Circuit: >360A 100-300us
- Temperature Protection: <-20°C or >75°C, Delay 1-2S (Recovery when >-10°C or <65°C)
- BMS Features
- PCB Temp Protection: >115°C Delay 1-2S Recover when <80°C
- Cell Balance: 20-30mA passive balance cell voltage difference > 40mV
- Temperature Accuracy: ±2°C Cycle measurement Measuring range -40 to 100°C
- Voltage Accuracy: ±20mV Cycle measurement for cells and module
- Current Accuracy: FSC±5% Cycle measurement measuring range -200 to +200
- SOC: 5% (integral calculation)
- Power Consumption: <300ua switch="" off="" mode="" -="" storage="" 100ua="" sleep="" protection="" standby="" 15ma="" operating="" li="">
Delivery varies by location, please see the expected timeframe to receive your product below:
Metro: 1-4 business days
Regional: 3-10 business days
If you are unavailable at the time of delivery re-delivery fees may apply.
Change of Mind Returns:
We want you to love your product so if you are not completely satisfied with your purchase let us know.
Most products come with a 30 day change of mind policy. If at any time within the first 30 days from purchase date you are not completely satisfied with your order, please contact us for return approval. Once received and inspected, we will facilitate an agreed resolution.
Please Note:
-
Postage is paid by the customer
-
The product must be returned in the original packaging, accessories included
-
We do not accept responsibility for return items until they reach our warehouse, so we strongly recommend using tracking and/or insurance for the delivery
-
Fees may apply
Warranty Claims:
Most of our products are supported by a 12 month warranty. This warranty covers all manufacturer faults with the product. Some of our products may have a different warranty period, please check the product description for this. Should an issue arise with your order, please contact us to raise a warranty claim.